19
PME-MP70DP
A0658-7.3 en
HBM
Control inputs and control outputs are available for the
MP70DPS7
and
MP70S7
variants:
4.2.1 External supply voltage for control outputs
Example: PLC connection
OUT3
24 V*
0 V*
max. 0.5 A
MP70 module
PLC
Relay
0 V*
max. 0.5 A
OUT1
Plug terminal 4
24 V
Fig. 4.2:
Connection to a PLC
The control
inputs
are available at plug terminal 3, the control
outputs
at
plug terminal 4, and are electrically isolated from the internal supply voltage
(also see chapter 8, “Clarification of important parameters", page 38).
*
)
The control outputs must be supplied with an external voltage
(ground
and
24 V).
4.3
PROFIBUS
PROFIBUS
connector socket
1
5
6
9
GND
RS485‐RTS
RS485‐B
RS485‐A
Vcc (5 V)
Fig. 4.3:
PROFIBUS connection as per standard