71
PME-MP70DP
A0658-7.3 en
HBM
Current errors are displayed continuously (also see page 29). Press
+
, until
you arrive at “ERROR" display mode.
Error message
Cause
Remedy
ErrSlave
1)
Input signal overflow
Eliminate error in slave
AnlgOutp
2)3)5
)
(AnlgOvfl)
Analog output overflow
Check display value‐analog
output assignment
PkValMin
(PkMinOvf)
Minimum peak value overflow
1. Use external remote control to
clear peak value or
2. In the PEAKVAL STORE
group, “PkClear" Yes
PkValMax
(PkMaxOvf)
Maximum peak value overflow
1. Use external remote control to
clear peak value or
2. In the PEAKVAL STORE
group, “PkClear" Yes
Net
5)
(Net+Ovf; Net‐Ovf)
Net value overflow
4)
Reduce display by one decimal
place
Gross
5)
(Grs+Ovf; Grs‐Ovf)
Gross value overflow
4)
Reduce display by one decimal
place
(InitCalErr)
5)
No valid initial calibration values
Restart, send the PME to the
manufacturer (HBM)
CAN Tx
5)
PDOs are not accepted at the bus
Check the CAN Bus
configuration
1)
Error messages without brackets: errors displayed continuously in “ERROR" display mode.
2)
Error messages in brackets: Errors displayed in the appropriate display mode (e.g. Gross, Net, Analog
output signal).
3)
for MP70DPS7 and MP70S7
4)
“
1 000 000
"
is output on the CAN Bus
5)
With the “Error at digital output" setting, the error message is displayed at the digital output
NOTE
The status of the MP70DP can be queried via the MP70DP device status.
A CAN slave fault can also be detected and indicated after about 10
seconds (bit 14). This bit is set when a number of errors are present on
the CAN Bus. This can include, for example, missing PDOs because a
CAN node has been lost. The exact time of the indication depends on
the number of nodes and the network load. This method of alarm
indication is therefore not suitable for high‐speed processes.