DIS2116
24
HBM
A2540-1.1 en/de
Execution is dependent on standstill recognition (Chapter 7.9, page 25).
Taring with this key overwrites any manual tare value that may have been ent-
ered previously (PT symbol is switched off).
Entering manual tare value
Pressing the F3 key for more than 2 s displays a window for input of a manual
tare value. Upon entry of a manual tare value, the net value plus manual tare
is displayed (NET PT).
NOTE
Taring and entry of a manual tare value is only possible when the function in
the ”PARAMETER MENU
→
FUNCTION KEYS
→
TARING” is set to ACTIVE.
7.6
Manual tare function
A manual tare value can be input in the parameter menu ”SCALE PARAME-
TERS-PARAMETER-MANUAL TARE VALUE” and the calculation of the ma-
nual tare value can be switched on/off in the parameter menu ”SCALE PARA-
METERS-PARAMETER-MANUAL TARE MODE”, (see system CD).
When the ”Manual tare” function is active, the net value is formed by deduc-
ting a fixed tare value.
The ”G/N” key does not change the entered manual tare value.
The
.
PT
.
symbol in the display indicates that the net value has been formed by
deducting the manual tare value. This disappears after taring with the key F3
(”>T<”).
If the tare function was activated, it will also be activated once the device is
switched back on.
7.7
Zero on start-up
If this function is activated (parameter menu ”SCALE PARAMETERS
→
PARA-
METER
→
ZERO ON START-UP”), the unloaded scale is automatically set to
zero when the DIS2116 is switched on (range of zero setting device
±
2...20 %).
This takes into consideration the set standstill condition.