DIS2116
38
HBM
A2540-1.1 en/de
Measurement
Error code
Description
Remedy
50xx
Load cell with address xx not supplying
measured value
Carry out busscan or test load cell (Test
menu), emergency operation possible if
only one load cell fails per segment
51xx
Load cell with address xx has incorrect F
number
Reload load cell with parameters (Menu
Adjust/Repair) or replace load cell
52xx
Load cell with address xx has incorrect TRC
status
Reload load cell with parameters (Menu
Adjust/Repair) or replace load cell
5701
Vehicle empty weight > Weighing2 result
Check vehicle data
Repeat measurement if necessary
5702
Weighing result < minimum vehicle weight
Adjust minimum vehicle weight
Vehicle loaded
5703
Weighing result > maximum vehicle weight
Adjust maximum vehicle weight
Vehicle overloaded
5801
Measurement invalid
Printout measured value at 0
Printout 2x same measured value
5802
No standstill
Standstill conditions not applicable
during measured value printout
Off-center load compensation
Error code
Description
Remedy
6001
Measured value differences in corners too
large
6002
Zero point outside off-center load range cannot
be compensated
Check scale construction
6003
Nominal value outside off-center load range
cannot be compensated
Database
Error code
Description
Remedy
7001
Yard list full (50 entries)
7002
Database error
Repair database (Menu FACTORY
SETTINGS−DATABASE)
COM1−4 interfaces
Error code
Description
Remedy
8x01
Input buffer overflow
8x02
Overrun
Possible causes:
Incorrect baud rate, parity settings
Carry out a BUSSCAN
8x03
Parity error
Possible causes:
Incorrect baud rate, parity settings
8x04
Framing error
Possible causes:
Incorrect baud rate, parity settings
Carry out a BUSSCAN
8x05
Framing error
Possible causes:
Incorrect baud rate, parity settings
x represents the interface e.g. 8101 error at COM1, 8201 error at COM2, etc.