DIS2116
23
HBM
A2540-1.1 en/de
7.3
Gross/net selection
Press the F4 key until the symbol appears above the F2 key.
Every time the F2 key is pressed, the display changes between gross and net.
When selecting the net display, the last valid tare value is used again.
NOTE
Gross/net selection is only possible when the function in the ”PARAMETER
MENU
→
FUNCTION KEYS
→
GROSS/NET” is set to ACTIVE.
7.4
10-fold resolution
Press the F4 key until the display symbol x10 appears above the F2 key.
Every time the F2 key is pressed, 10x resolution is switched on/off. This mode
can be used for test purposes. The measured value is then displayed with a
factor 10 higher resolution.
NOTE
10-fold resolution is only possible when the function in the ”PARAMETER
MENU
→
FUNCTION KEYS
→
10-FOLD RESOLUTION” is set to ACTIVE. If
the scale is set to legal-for-trade OIML or NTEP, 10-fold resolution can only be
switched on while the F2 key is pressed. When F2 is released, 10-fold resolu-
tion is switched off after 5 s.
7.5
Taring
Press the F4 key until the symbol >T< appears above the F3 key.
Pressing the F3 key stores the current gross value and deducts it from all the
subsequent weight values. The displayed (net) value is zero immediately after
taring. The tare value can be permanently displayed in the measurement va-
lue display, the setting must be made in the menu ”DISPLAY-DISPLAY-LINE1”
or ”DISPLAY-DISPLAY-LINE2”. The tare value can be read in the ”INFORMA-
TION-TARE VALUE” menu item.
MODE
³
LEGAL-FOR-TRADE
Tare range, lower limit
Tare range, upper limit
NO (not legal for trade)
−100 %
100 %
OIML, NTEP
>0
100 %
The % figures relate to the nominal weighing range (parameter ”SCALE PA-
RAMETERS
→
PARAMETER
→
NOMINAL VALUE”)