used for freeze protection. Temperature is adjustable from 33ºF-
42ºF (1ºC-6ºC). 38ºF (3ºC) is default. This threshold will be used for
all outputs that have freeze protection enabled.
If VSP is selected:
Which Hayward Unique Address?
If using a VSP, you’ll be asked what is the
Hayward Unique Address (HUA). If a value is already shown in the box, advance
to the next screen. If no value is shown, selecting the box will bring you to a
table showing all detected devices. Select the proper HUA from the table and
touch the Done button. If unsure of the HUA, refer to the pump’s manual for
instructions on how to determine the pump’s HUA. Once selected, the address
should now be shown in the box and you can advance to the next screen to
continue the VSP configuration.
Pump Capacity -
Set the minimum and maximum RPM of the pump. Refer to
your pump manual for more information.
Permitted User Setting -
The OmniPL will automatically calculate these values
based on the minimum and maximum RPM that were previously entered. They
can be changed as desired.
Speed Presets -
Set the Low Pump Speed %, Medium Pump Speed %, and
High Pump Speed %, presets. These presets will be used when setting sched-
ules for your pump.
Filter Pump Off for Valve Change?
When Yes is selected, the pump will shut
off for 35 seconds whenever the valve(s) change position.
Flow Monitoring Enabled?
Requires use of a Hayward flow switch.
This fea-
ture will help protect the filter pump from damage due to no flow. When Yes is
selected, the OmniPL will monitor the state of water flow when the filter pump is
on. If no flow is detected for more than 15 minutes, the OmniPL will shut down
the pool pump and will indicate an error. The error will be cleared the next time
the pump is turned on.
Would You Like to Enable Priming?
Select whether you want the filter pump
to prime when turned on. This will turn the pump on at high speed for 3 min-
utes to establish normal water flow every time the pump is activated after being
off for at least 30 seconds.
Freeze Protection Enabled?
Freeze protection is used to protect the pool and
plumbed equipment against freeze damage during cold temperatures. If freeze
protection is enabled AND the air temperature falls below the freeze threshold,
the OmniPL will turn on the filter pump to circulate the water. If two Bodies of
Water are configured, the valves will also alternate between the pool and spa
every 30 minutes and the filter pump will turn off while the valves are turning.