Lights
A ground fault circuit breaker (GFCB) must be used to supply power for high voltage pool/spa light-
ing. Low voltage lights will require an external transformer. For lighting systems that have both a
light source and color wheel, connect the light source to one relay and then connect the color wheel
to a different relay.
Universal ColorLogic Lights (UCL):
The OmniPL can be configured to synchronize multiple UCLs,
even if their low voltage transformers are not wired to the same relay. If UCL(s) will be running in
Omni Direct mode (lights built after June 2018), the transformer(s) can be wired to either an internal
relay or a Smart Relay. Refer to your Universal ColorLogic manual for more information about Omni
Direct mode.
Hayward Variable Speed Pump
Proper installation of a Hayward Variable Speed Pump (VSP) includes high voltage input wiring, low
voltage communication wiring, and menu configuration/settings. The OmniPL can control up to 16
EcoStar VSPs without the use of a relay. Refer to the adjacent diagram for proper 220VAC input
wiring to the VSP. Refer to “Low Voltage Wiring” section in this manual for information on commu-
nication wiring. Refer to the VSP manual(s) for detailed wiring information.
Variable Speed
Pump
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
18