Load short circuit
The current flowing is inadmissibly high.
-
Wiring error
-
Insulation damage
-
Heating
Collective alarm
Internal bus error
No communication to the affected power
board.
-
Identical address
assignment
-
Communication
disrupted
-
Terminating
impedance
-
Defective hardware
Collective alarm
Sensor short circuit
The present temperature does not change
when the assigned heating unit is heated
up
-
in the controller
-
in the connecting cable
Collective alarm
System fault
The power board has detected a hardware
fault.
-
Internal hardware fault
Collective alarm
5.3.2.3
Plotter
1.
2.
Operation > Plotter
The plotter is used to analyse the control behaviour of zones by displaying the profile over time of the process values
for actual value, setpoint value and output level on a curve diagram.
The curve is shown in the window with a black background. On the right of the screen are the arrow keys that can be
used to select the zones for the display. Only one zone at a time is displayed in the curve window, with the three process
values of actual value, setpoint value and output level. The process values to be displayed can be determined by clicking
on the process value in question. If the process value is marked with a tick it will be displayed – if it has no tick, the
process value will be hidden.
At the bottom of the screen there are additional buttons that can be used for the following settings:
15 min The plotter displays a time range of 15 minutes.
60 min The plotter displays a time range of 60 minutes.
4 h
The plotter displays a time range of 4 hours.
Zoom in
The plotter’s display range is reduced
Zoom Out
The plotter’s display range is enlarged