28 HASCO hot runner
T [°C]
20
-20
Zone 1
Monitoring
Actual [°C]
250
Setpoint [°C]
230
T [°C]
10
-10
Zone 1 in monitoring mode with the actual value, setpoint value
and the graphic control deviation.
Process values in monitoring mode are shown in orange.
The yellow bar indicates that the actual value is outside the
tolerance range.
In the example, the tolerance range is 10° and the control
deviation 20°.
Zone 1
Group*
Actual [°C]
235
Y [%]
25%
Active zone with the actual value and output level display.
Zone 1 is heated up in a group.
“*” means that this zone is the most inert in the heating group.
All the other zones in the heating group show “group” without an
“*”.
Zone 1
Optimised
Actual [°C]
235
Y [%]
25%
After it is switched on, the controller establishes the optimum
control parameters (automatic optimisation).
As soon as the optimum control parameters have been found,
the word “Optimised” will disappear.
Zone 1
Manual
Actual [°C]
235
Setpoint [°C]
238
Zone 1 in manual operation
Process values in manual operation are shown in blue.
Actual [°C]
200
Setpoint [°C]
238
Zone with fault indication “Negative temperature deviation”.
The warning signal with the yellow background flashes.
Pressing the warning signal will call up the diagnosis.
Zone 2
Actual [°C]
235
Setpoint [°C]
248
Y [%]
(70%)
Active zone with 3 process values:
In this example:
- actual value
- setpoint value
- output level: the output level is currently limited to 70%.
Zone 1
Monitoring
Actual [°C]
250
Y [%]
Zone 1 in monitoring mode with actual value and output level.
The output level display remains empty because no output level
is output in monitoring mode (outputs are switched off).