MODU-FIRE
®
Forced Draft Gas-Fired Boiler 2500-3000
6
the provisions of this manual are not fully and completely understood, contact the Harsco Industrial, Patterson-
Kelley Technical Services Department at (877) 728-5351.
2.3 S
AFETY
F
EATURES
It is the responsibility of the customer to maintain the safety features of this machine, such as: guards, safety
labels, safety controls, interlocks, lockout devices.
2.4 S
AFETY
L
ABELS
The following words are used in this manual to denote the degree of seriousness of the individual hazards.
The safety labels shown below are affixed to the boiler and dual language labels may also be affixed to the boiler.
Although the labels are of high quality, they may become dislodged or unreadable over time. Contact Harsco
Industrial, Patterson-Kelley for replacement labels.
2.5 S
AFETY
P
RECAUTIONS
Provide a suitable location for the boiler, away from normal personnel traffic, with adequate working space,
adequate clearances, proper ventilation and lighting, with a structure sufficiently strong and rigid to support the
weight of the boiler, all piping and accessories.
2.5.1 Electrical
Hazards
Shock hazard! Properly lockout/tagout the electrical
service and all other energy sources before working on or
near the machine.
Shock hazard! Boiler is not rated for wash-down service.
Power down unit for at least 10 minutes before servicing
the blower.
indicates an imminently hazardous situation which, if not avoided,
will
result
in death or serious injury. This signal word is to be limited to the most extreme situations.
indicates a potentially hazardous situation which, if not avoided,
could
re-
sult in death or serious injury.
indicates a potentially hazardous situation which, if not avoided,
may
result
in minor or moderate injury. It may also be used to alert against unsafe practices.
NOTICE/NOTE
- NOTICE is the preferred signal word to address practices not related to personal
injury. The safety alert symbol is not used with this signal word.
Содержание 1004905923
Страница 2: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 2 ...
Страница 31: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 31 Ratio V Adjust at Hi Fire Bias N Adjust at Low Fire ...
Страница 45: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 45 6 1 3 Wiring Schematic ...
Страница 48: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 48 6 1 6 Rear Junction Box ...
Страница 49: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 49 6 1 7 Customer Connections ...
Страница 56: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 56 ...