MODU-FIRE
®
Forced Draft Gas-Fired Boiler 2500-3000
8
2.5.3 Crush
Hazards
Lifting hazards! Use properly rated lifting equipment to lift and position the boiler. The load is
unbalanced. Test balance before lifting more than 3 ft. above the floor. Do not allow
personnel beneath the lifted load. The approximate weight of the N2500 & N3000 MFD is
1200 lbs.
Bump hazard from overhead piping. Install piping with adequate vertical clearance.
2.5.4 Chemical
Hazards
Chemical hazards from cleaning products. Use caution when cleaning the system. The use
of professional assistance is recommended. Use safe procedures for the disposal of all
cleaning solutions.
2.5.5 Pressure
Hazards
Pressure hazard! Hot fluids. Install isolation valves on boiler water inlet and outlet. Make
sure isolation valves are closed before servicing boiler.
Pressure hazard! Hot fluids. Test safety relief valve every 30 days during the heating season
and after any prolonged period of inactivity. Do not operate boiler with faulty relief valve.
2.5.5 General
Hazards
Tripping hazard! Do not install piping on floor surfaces. Maintain clear path around boiler.
Slip and fall hazard! Use drip pan to catch water while draining the boiler. Maintain dry floor
surfaces.
Slip and fall hazard! Through-the-wall vents shall not terminate over public walkways or over
an area where condensate or vapor could create a nuisance or hazard.
Fall hazard! Do not stand on any part of the boiler.
Catch hazard! Do not wear rings, jewelry, long hair, loose clothing while working on the
boiler.
3 INSTALLATION
Installation and service must be performed by a qualified installer, service agency,
or gas supplier.
3.1 R
ECEIVING AND
S
TORAGE
3.1.1 Initial
Inspection
Upon receiving the boiler, inspect it for signs of shipping damage
. Since some damage may be hidden, we
recommend unpacking the boiler, removing the top, front, and side covers and inspect the boiler. Verify that the
total number of pieces shown on the packing slip agrees with those actually received.
General Warning
General Warning
General Warning
General Warning
Содержание 1004905923
Страница 2: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 2 ...
Страница 31: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 31 Ratio V Adjust at Hi Fire Bias N Adjust at Low Fire ...
Страница 45: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 45 6 1 3 Wiring Schematic ...
Страница 48: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 48 6 1 6 Rear Junction Box ...
Страница 49: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 49 6 1 7 Customer Connections ...
Страница 56: ...MODU FIRE Forced Draft Gas Fired Boiler 2500 3000 56 ...