12/20/11
888-2595-001
6-5
WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
ZX Series
LOW FAN SPEED
alarm
One or more chassis fans have not achieved full speed. Consult individual
fault LEDs on transmitter rear door to determine which fan is affected.
Physical arrangement of fault LEDs on rear door mimics physical layout of
fans on rear door. Possible indication that fan bearings are failing. Replace
fan at earliest convenience, especially if fan is greater than five years old or is
especially noisy. Note that transmitter can run for extended periods with a
failed fan.
If desired, swap affected fan feed cable with adjacent fan cable on fan alarm
board (reverse side of rear door) and verify alarm follows fan/fan cable. If
alarm stays in same position, proceed to replace fan alarm board.
It is normal for this alarm to be present when transmitter is switched off.
It is normal for this alarm to be reported for up to thirty seconds after
transmitter start up if all fans do not start instantly.
AC MAINS LOW
alarm
One or more AC inputs has voltage below 190V threshold. Inspect AC>90V
lights on PS modules and/or AC FAULT LEDs on wall behind PS modules (to
right) to determine which input(s) are affected. Consult component locator
sticker to right of controller board for aid in locating AC FAULT LEDs in
chassis.
Possible open circuit breaker(s). Inspect and reset circuit breakers. Verify
correct breaker sizing versus recommendations in
Outline Drawing
in
accompanying drawing package.
Possible open fuse or other failure of mains detection circuit on PS interface
board. Each AC mains input has separate detection circuit to trigger an alarm
in input falls below 190V.
Table 6-2 Controller Board Alarm LEDs
Symptom
Cause and Solution
Содержание ZX10
Страница 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 80: ...3 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 3 Operation ZX Series ...
Страница 162: ...6 16 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 6 Troubleshooting ZX Series ...
Страница 174: ...7 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 7 Parts List ZX Series ...