12/20/11
888-2595-001
5-37
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
ZX Series
NOTE:
Some users prefer to leave these four cables attached until the output assembly is
already outside the chassis. Excess cable length has been provided for these
cables for this purpose.
STEP 8
Loosen four black thumbscrews on base of output assembly to free
assembly from chassis wall.
STEP 9
Rotate outward bottom end of output assembly base.
STEP 10
Pull RF output connection back inside transmitter chassis and remove
entire output assembly from transmitter.
STEP 11
Prepare chassis to accept replacement output assembly by tucking 20C
ribbon up out of way e.g. up inside cable connections to PS interface
board.
STEP 12
Support replacement output assembly close to transmitter entrance and
attach mini-coax cables to forward monitor, reverse monitor, forward
meter, and reverse meter coupling ports. If a wrench is used to tighten
SMA connections, do not over-tighten. Use only minimum force
required to make a snug connection.
STEP 13
Verify new output assembly has SMA loads installed where indicated on
forward and reverse meter couplers. If not, transfer SMA loads from
original output assembly.
STEP 14
Introduce new output assembly into transmitter at 45 degree angle with
bottom of base rotated to right.
STEP 15
Insert RF output connection through rear transmitter wall and rotate
output assembly bottom toward left until heatsink base lies flush against
transmitter interior wall. Be careful to not crush any cables trapped
beneath heatsink base.
STEP 16
Tighten four thumbscrews to attach base to chassis interior wall.
STEP 17
Attach 20C ribbon cable to 16X load board on output assemble lower
deck. Look up through air holes in combiner support frame to see and
align connection.
STEP 18
Connect BNC cables to PA backplane RF outputs. Ensure that yellow-
labeled BNC cables are only attached to “upper” output, while white-
labeled BNC cables are only attached to “lower” output on each
backplane card. Consult amplifier
RF Interconnect Wiring Diagram
in
accompanying drawing package for correct cable connections.
STEP 19
Dress BNC coax cables with cable ties, as desired.
Содержание ZX10
Страница 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 80: ...3 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 3 Operation ZX Series ...
Страница 162: ...6 16 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 6 Troubleshooting ZX Series ...
Страница 174: ...7 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 7 Parts List ZX Series ...