2-6
888-2595-001
12/20/11
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
ZX Series
The ZX2500 and ZX3750 amplifier chassis have three 208-240 VAC 50/60Hz single-
phase feeds via IEC C20 inlets. The three inputs are completely independent and may
be wired to separate AC phases for increased redundancy.
The ZX5000 amplifier chassis has three 208-240 VAC 50/60Hz single-phase feeds via
Powercon NAC3MPA connectors. The use of Powercon connectors is dictated by the
greater current requirements of the ZX5000 chassis. The three inputs are completely
independent and may be wired to separate AC phases for increased redundancy.
NOTE:
Examine the connectors closely to find the L, N and PE (ground) designations.
Connector wiring information can be found on the mains interconnect drawing.
Since the three mains inputs are essentially independent, it is not necessary to observe a
certain phase rotation or even phase balance in three phase systems. Additionally, the
amplifier chassis can operate indefinitely (at a reduced power) with one or two of the
mains inputs missing. The internal power supplies connected to each input will
continue to operate provided that the incoming mains power at that input falls within
the 190V – 264V range indicated above.
NOTE:
The transmitter and internal power supply modules have been certified by an
accredited testing laboratory for a nominal mains voltage range of 208V-240V.
This certification requires testing to an over- and undervoltage allowance of +/-
10%. Accordingly, there may discrepancies in certain documents depending on
whether the certified nominal voltage range (e.g. 240V) or maximum tested volt-
age range (240V + 10% = 264V) is specified.
Consult the transmitter
Outline Drawing
and
Mains Interconnect
drawing for
information concerning suggested wiring diameters and fusing requirements.
!
WARNING:
AN EXTERNAL CIRCUIT PROTECTION DEVICE (BREAKER OR FUSE) IS REQUIRED
FOR EACH EXCITER AND POWER AMPLIFIER AC INPUT. THIS IS PROVIDED BY
THE CUSTOMER IN ACCORDANCE WITH THE MAINS INTERCONNECT DRAWING
OR BY HARRIS IF AN IN-RACK AC DISTRIBUTION CHASSIS IS SUPPLIED. IN THE
LATTER CASE, AN EXTERNAL CIRCUIT PROTECTION DEVICE TO COVER THE
ENTIRE TRANSMITTER LOAD AT THE MAIN AC DISTRIBUTION POINT IS STILL
REQUIRED, IN ACCORDANCE WITH PREVAILING LOCAL SAFETY NORMS
.
!
CAUTION:
WHEN THE TWO OR THREE SINGLE PHASE INPUTS TO THE TRANSMITTER ARE
DERIVED FROM A WYE (STAR) MAINS SERVICE, SPECIAL CARE MUST BE PAID
TO THE NEUTRAL CONNECTION, AS THE NEUTRAL CONNECTION SERVES AS
Содержание ZX10
Страница 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 80: ...3 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 3 Operation ZX Series ...
Страница 162: ...6 16 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 6 Troubleshooting ZX Series ...
Страница 174: ...7 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 7 Parts List ZX Series ...