5-24
888-2595-001
12/20/11
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
ZX Series
power using PA chassis front panel meter, not system metering assembly
forward meter.
STEP 7
Switch on upper PA chassis via its front panel ON button. Both chassis
should be active and power should rise to full desired level at system
metering assembly forward power meter. (e.g. 10kW in present
example)
STEP 8
Adjust APC LIMIT for current transmitting mode in upper chassis (only)
to fine trim total power level.
NOTE:
It is not necessary to fine adjust the lower PA chassis because the transmitter
power control is only tracking the upper amplifier APC circuit. The lower ampli-
fier APC circuit is waiting in reserve.
STEP 9
Place both amplifier chassis in REMOTE ENABLED mode on their
respective controllers.
STEP 10
Press POWER LOWER and/or POWER RAISE pushbuttons on either
controller to verify power is adjustable over a 10%-100% range.
STEP 11
Repeat procedure as desired for other transmitting modes (e.g. FM,
FM+HD, HD)
STEP 12
If frequent mode switching is envisioned, fine tune APC LIMIT
potentiometer settings for various modes in upper PA chassis (only) to
ensure power always returns to 100% for each new mode after
switching.
STEP 13
Procedure complete.
5.4.7
Set User Reverse Power Foldback Threshold
(
ZX2500 / ZX3750 / ZX5000)
Use this procedure to set the user-defined reverse power foldback threshold for all
single PA-chassis transmitter models. The user reverse power foldback is designed to
reduce power when the average reflected power at the transmitter output exceeds a
given level set by the user.
Tools required:
Nut driver 8mm (7/16)
(to break output transmission line)
Small adjustment screwdriver
STEP 1
Select reverse power metering position via meter select pushbutton on
amplifier front panel.
Содержание ZX10
Страница 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 80: ...3 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 3 Operation ZX Series ...
Страница 162: ...6 16 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 6 Troubleshooting ZX Series ...
Страница 174: ...7 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 7 Parts List ZX Series ...