12/20/11
888-2595-001
A-7
WARNING: Disconnect primary power prior to servicing.
Appendix A - FM Web Remote Option
ZX Series
STEP 5
Erase last letter of password key from input box at upper right at any
time to pause readings. Restore key to cancel pause and resume
operations.
STEP 6
Press command buttons as desired to affect transmitter operation.
STEP 7
Press MAIL button to generate auto e-mail message populated with
current readings.
NOTE:
The automated e-mail feature requires that a valid e-mail client be previously
installed and activated on the PC accessing the web remote. This automated e-
mail facilitates the tasks of logging transmitter readings by allowing the user to
simply archive the populated e-mail in an e-mail folder for future reference. It
also provides an easy means to communicate transmitter readings to Harris Cus-
tomer Service personnel.
STEP 8
Procedure complete.
Table A-1 Elements on main page.
STATUS BAR
STATUS BAR
(top compartment)
Provides a space to enter password key (right), displays transmitter ID name
(center), and changes color to provide at-a-glance assessment of transmitter status.
[Green/Yellow/Grey/White]
[Green] = transmitter is switched on with no active faults.
[Yellow] = transmitter is switched on but has active faults.
[Grey] = transmitter is switched off.
[White] = web remote is awaiting password or has lost serial data link.
METER READINGS
SYSTEM FWD kW
Transmitter system forward output power. This reading is obtained from an RF
detector in the ZX System Metering Panel (981-0090-070), when installed.
If the system metering panel is marked as NOT installed on the configuration page,
this reading is a repetition of the PA FORWARD WATTS reading from the RF
detectors inside the amplifier chassis.
SYSTEM REV kW
Transmitter system reverse output power. This reading is obtained from an RF
detector in the ZX System Metering Panel (981-0090-070), when installed.
If the system metering panel is marked as NOT installed on the configuration page,
this reading is a repetition of the PA REVERSE WATTS reading from the RF
detectors inside the amplifier chassis.
Содержание ZX10
Страница 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...