12/20/11
888-2595-001
A-17
WARNING: Disconnect primary power prior to servicing.
Appendix A - FM Web Remote Option
ZX Series
A.5.2
Perform Simple Reset
Purpose
: Issues simple reset of microprocessor. Essentially the same as cycling power
to card.
Special Tools
: Small plastic screwdriver.
STEP 1
Locate WEB RESET hole on I/O panel at upper rear face of amplifier
chassis. (See Figure A.6)
STEP 2
Press button continually with small plastic adjustment tool or similar
item for ten seconds. Maintain button depressed continually for full ten
seconds.
STEP 3
Web remote processor resets and will resume operation within seconds
of button release.
STEP 4
Procedure complete.
WRITE
COMMUNITY
The SNMP WRITE community for SET commands.
VALID SET VALUE
As an added security measure, the value “written” by the SNMP SET must match
this value. Otherwise, no command will be issued.
SNMP TRAP
ENABLED
Enables alarm notification of an RF < ALARM THRESHOLD fault via a generic
SNMP trap. Toggling this setting from 0(off) to 1(on) will cause a test trap to be
sent.
SNMP TRAP
ADDRESS
The destination IP address of the trap notification.
VERSION
The software version of the web remote.
Table A-3 List of settings on configuration page.
Содержание ZX10
Страница 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ...
Страница 18: ...Table of Contents Continued 4 ...
Страница 80: ...3 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 3 Operation ZX Series ...
Страница 162: ...6 16 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 6 Troubleshooting ZX Series ...
Страница 174: ...7 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 7 Parts List ZX Series ...