GENERAL: 

 

The RX4100 communicates with all H-ITT RF clickers. There is no limit to the number of RF clickers that can be used with the RX4100. 
The RX4100 has 31 RF channels that can be selected and are provided so that a classroom may have a unique RF channel to avoid 
interference between another device in or about the classroom. The RX4100 is initially set to 
channel  07  to  operate  with  H-ITT  RF  clickers  that  are  also  initially  set  to  channel  07.  The 
RX4100 has selectable baud rates for communication to your PC. The default setting is 19.2K 
baud.  Higher  Baud  rates  are  available,  but  typically  not  needed.  If  higher  baud  rates  are 
selected, the length of the USB cable should not exceed 15 feet. 

 

 

Connecting the RX4100

 

1. 

Attach the antenna to the SMA connector on the back of the RX4100. 

2.  Connect the RX4100 to your classroom computer with the supplied USB cable.  

Upon  connecting  the  USB  the  YELLOW  power  indicator  light  will  turn  on  and  both  the 
GREEN PC com and RED RF com indicators will blink 4 times each. 

 

That’s it for hardware connection!

 

Install the software

 

Depending on your operating system (Windows, Mac or Linux) you may need to install USB 
drivers for the hardware to properly communicate with your computer. The USB drivers vary 
depending on your computers operating system; Windows and Mac require driver installation 
where  Linux  drivers  are  built  in.  Windows  and  Mac  USB  drivers  are  included  on  the  CD 
supplied with the RX4100. Insert the H-ITT CD into your drive, the menu should pop-up in a 
few seconds (depending on your OS and settings), if not, browse to your CD drive and double 
click the file name “index.htm”. Under the “drivers” section, click the link and download (save 
to your computer) the appropriate USB driver for your operating system. USB drivers are also 
provided  at  H-ITT.COM  from  the  download  links  where  you  will  find  instructions  based  on 
your operating system.

 

Windows users note:

 When the RX4100 is first 

connected a “found new hardware” wizard 

will pop-up. If you are connected to the Internet, this wizard can locate and install the proper 
drivers;  accept  the  wizard  defaults  and  the  required  USB  drivers  will  be  installed  in  a  minute  or  so.  If  you  are  not  connected  to  the 
Internet click on and download the link “2000/XP/Vista auto installer” to your computer, either from the CD or from H-ITT.COM. Install 
the  drivers  by  double  clicking  the  download  (i.e.  CDM  2.02.xx.exe).  After  a  few  seconds  a  prompt  will  verify  successful  driver 
installation.

 

 

TEST 

 

With the RX4100 connected, 

using a H-ITT RF remote press a button (A/1 through J/0) on the RF remote and verify: 

 

On the RX4100, the YELLOW power indicator is on and the GREEN PC Com light and RED RF com lights blink.  

 

On the RF remote, the indicator light turns green (confirmation from the base to the remote that valid data is received) . 

 

This verifies that the hardware is set correctly. If test fails, check the yellow power light is on (power supplied from the  USB cable) and 
that the RF channel on both the RX4100 and the remote you are testing with are the same (check set-up switches, and remote).

 

Test  with  H-ITT  software

 

to  make  sure  the  RX4100  is  communicating  with  your  computer  using  the  H-ITT-CRS  Acquisition 

pr

ogram. When the RX4100 is connected, the initial screen of the Acquisition program will show under “Port and Base Unit Type”  a 

COM port labeled “USB Serial Com Port x”. When a remote is activated, the remotes serial number will appear under the “Detected 
R

esponses” column which shows both the remotes serial number and the key pressed.

 

If the ”USB Serial Com Port x” does not show up, it is most likely the USB drivers are not installed, see above to install USB drivers or 
contact H-ITT support for assistance. If the com port shows up, but remote serial numbers do not show up it is most likely a baud rate 
mismatch. Verify the set-up switch is set for 19.2K baud (switches 7&8 in the ON position), and Acquisition baud setting under the blue 
“change” text shows 19.2K baud.

 

Test the RX4100 installation: 

To ensure reliable communication between the RX4100 and remotes for your application, go to the 

far  corners  of the expected coverage  area  (or  from  worst  case seat  positions)  and  verify  the  remotes green  light  turns  on  with  a key 
press, this is the remotes acknowledgement that the key press was received by the RX4100 and communicated to the computer.

 

Your H-ITT hardware is now ready

 to collect and process responses from remotes with H-

ITT’s applications software. H-ITT 

offers several programs that allow you to teach your class your way. Click the link on the CD “Learn More About H-ITTs Software” or 
visit H-ITT.com software links for more information.

 

 

Contact info: 
Additional  information  regarding  installation,  applications  and  software  can  be  found  at 

http://www.h-itt.com

. You can e-mail 

[email protected]

 or call toll free 1-888-322-

0089 for technical assistance with any problems installing or using your H-ITT product. 

For Sales, phone: 877-244-4488, or email 

[email protected]

 

Rev 1.0 

Antenna 

Power 
indicator 

PC com 
indicator 

RF com 
indicator 

USB cable 

H-ITT, LLC 
420 Shearer Blvd 
Cocoa, FL 32922 

Отзывы: