5 – Web Browser Interface Configuration & Operation
HD Link Installation & Operation Manual
Version 2, April 2010
Harris Corporation
5-17
Intraplex Products
Transmitter Parameters
●
On/Off
: Click this button to turn the transmitter power on or off.
●
Power amplifier voltage
: Current amplifier voltage.
●
Forward power
: Measured actual output power, in watts.
●
Reflected power
: Level of output power being reflected back to the transmitter, in watts.
●
VSWR
: Current Voltage Standing Wave Ratio.
●
Output Power
: Click an option to configure the transmitter output power:
•
1 watt
•
2 watts
•
5 watts
●
Power amplifier current
: Current value of the power amplifier.
●
Low forward power alarm threshold
: Sets the lowest possible value, in milliwatts, for the
forward power before an alarm is generated. The low forward power alarm threshold setting must
be between 9 and 7000, inclusive.
●
High forward power alarm threshold
: Sets the highest possible value, in milliwatts, for the
forward power before an alarm is generated. The high forward power alarm threshold setting must
be between 0 and 7000, inclusive.
●
Reflected power alarm threshold
: Sets the highest possible value, in milliwatts, of the
reflected power before an alarm is generated. The reflected power alarm threshold setting must be
between 0 and 7000, inclusive.
●
VSWR alarm threshold
: Set the highest possible value of the VSWR before an alarm is
generated. The VSWR alarm threshold setting must be between 0 and 5, inclusive.
●
Reset
: Click this button to return all settings back to their values when the page was loaded or
last saved.
●
Save
: Click this button to record and apply your configuration changes.
Receiver Parameters
●
On/Off
: Click this button to turn the receiver power on or off.
●
Signal-to-Noise ratio
: Current SNR in decibels. If the receiver cannot locate a signal, a yellow
Acquiring
message appears in this field.
●
Received signal level
: Signal level currently received, in dBm.
●
Front end received signal level
: Signal level currently received at the front end, in dBm.
●
Receiver lock status
: Whether the receiver has locked onto a signal from the transmitter:
Locked
(green) or
Unknown
(red)
●
Modem lock status
: Yellow
Acquiring
message appears in this field if the receiver cannot locate
a signal.
●
Signal-to-Noise alarm threshold
: Current SNR alarm threshold, in dBm.
●
Received signal level alarm threshold
: Current alarm threshold for the received signal, in
dBm.
●
Receiver attenuation
: Receiver attenuation value. A “0” indicates no attenuation.
●
Reset
: Click this button to return all settings back to their values when the page was loaded or
last saved.
●
Save
: Click this button to record and apply your configuration changes.
Содержание Intraplex HD Link RF
Страница 4: ...No header Harris Corporation Intraplex Products This page is left blank intentionally ...
Страница 14: ...No header here viii Harris Corporation Intraplex Products This page is left blank intentionally ...
Страница 26: ...No header here 2 10 Harris Corporation Intraplex Products This page is left blank intentionally ...
Страница 104: ...No header here 4 70 Harris Corporation Intraplex Products This page is left blank intentionally ...
Страница 170: ...No header here Harris Corporation 6 10 Intraplex Products This page is left blank intentionally ...
Страница 180: ...No header here A 2 Harris Corporation Intraplex Products This page is left blank intentionally ...