2/25/03
888-2473-001
3-31
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ATLAS Series™
3.9.3
System Log
This screen is accessed by pressing the System Log button on the System screen in
Figure 3-30 on page 3-26. It is a complete listing of all transmitter and system faults
in the order in which they occurred. It can hold up to 99 faults and then becomes a
FIFO (First IN - First Out) memory buffer. Active Faults will be highlighted and
cannot be reset. All other faults will be cleared when the RESET button is pressed.
Figure 3-36 shows that only faults #31 and #36 are active, all other faults are
inactive. Use the Next and Previous buttons to view the entire list.
A complete listing of all faults which can show up in this log, along with a brief
explanation of each fault, is given in the following tables in Section 6, Diagnostics.
•
Table 6-1, “Atlas Transmitter Fault List,” on page 6-3
•
Table 6-2, “Atlas PA Module Fault List,” on page 6-6.
These tables are a quick reference list and in most cases is all that is required for
advanced user to diagnose the problem. However, detailed information on each of
these faults is also given in context with the fault page where it originated, also in
Section 6.
Figure 3-36 System Log Screen
To Figure 3-30
Note:
Date format is
DD/MM/YY
Содержание Atlas DVL400
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...