2/25/03
888-2473-001
1-15
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
ATLAS Series™
Performance
Equivalent Noise
Degradation (END)
dB
Measured per ETR 290
< 0.5
Modulation Error Ratio
(MER)
dB
At rated Power and -37 dB
shoulders (using HP89440)
Within the
performance
temp window
> 33 dB
Phase Noise
dBc/
Hz
After warm up time
-95@10Khz
Frequency stability
(without external
reference)
+/-
Hz
Stand alone transmitter
< 17
Frequency stability
(with external
reference)
+/-
Hz
Requires external 10 Mhz
< 0.1
Coarse Frequency
Offset Range
+/-
Mhz
In steps of 166 KHz
4
Fine Frequency Offset
Range
+/-
KHz
In steps of 1Hz
166
Transmitter Processing
Delay
msec
From TS input to RF output
Used in SFN
operation
programmabl
e to 1 sec max
Spurious Radiation
Harmonics and
spurious emissions
dBc
"After Mask Filter,
referenced to average
transmitter power"
Depends on
DTV Mask
requirement
of individual
countries
< -60
Harmonics before
Mask Filter
dBc
Transmitter output before
mask filter
< -40
AC Line
AC Line Voltage (3-
phase models)
VAC
3-phase 50/60 Hz
select one
"380, 400,
415"
AC Line Voltage (1-
phase models)
VAC
1-phase 50/60 Hz
"220,230,240
"
AC Line Voltage
Variation
%
"+10, -15"
Power Factor (3-phase
models)
"DVL1500, DVL2200,
DVL3000, DVL4300,
DVL5700"
> 0.94
Power Factor (1-phase
models)
"DVL
400,DVL800,DVL1100"
> 0.97
Overall Efficiency
(typical)
%
AC power to RF average
power
18% Typical
Table 1-2 Atlas Performance Specifications
Item
Units
Conditions
Notes
Value
Содержание Atlas DVL400
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...