2/25/03
888-2473-001
1-11
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
ATLAS Series™
* Each of these status indications is also sent to the transmitter for display on the
GUI and via remote control.
When in Remote mode, the transmitter is responsible for control of the cooling
system, including ON/OFF, manual pump selection and automatic pump switching
in the case of a failure. Placing the control panel in Local mode allows manual
switching of the pumps using the pump select buttons on the cooling control panel.
The lower half of the control panel contains the ac isolation switch which
disconnects ac power from the pump module and heat exchanger as well as the
control circuitry in the control panel itself.
1.2.6.2
Pump Module
The pump module is a self-contained unit with a storage tank, pressure and
temperature gauges, a strainer filter and one pump or the optional dual pumps
operating in main/standby mode. The pump module is an open frame unit and is
meant to be installed inside the building (with a special option for outside
mounting). The control panel is separate from the pump module and should be
mounted near the transmitter (usually next to the transmitter disconnect panel).
Figure 1-6 Simplified Liquid Cooling System Block Diagram
Medium Power (up to DVL 3000)
Содержание Atlas DVL400
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...