WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
ATLAS Series™
4.3.6.2
RF Mute Interlock
There are 2 more interlock connections on J18 which can be used to apply an RF
Mute; instead of a Fault OFF condition as discussed above. These are:
•
J18-9 to J18-10
•
J18-11 to J18-12
!
CAUTION:
THESE INTERLOCK CONNECTIONS ARE NOT TO BE USED IN ANY
SITUATION WHERE PROTECTION OF PERSONNEL IS AN ISSUE.
While this interlock can be used for any purpose where it is desired to mute the RF
temporarily, the primary purpose is for use on a flow switch of a water cooled
resistive load.
When the transmitter is first turned on there is little or no coolant flow. If the flow
switch is interlocked to the Fault OFF interlock (J18, 1-8), the transmitter cannot be
turned on. However, by connecting the flow switch to the RF Mute interlock, only
the RF output is held off until the coolant flow is present.
The RF Mute interlock can also be used for RF switch changeover or a dummy load
thermal interlock.