2/25/03
888-2473-001
6-3
WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
ATLAS Series™
6.3
Fault Tables
The following tables provide a listing of Atlas Transmitter faults along with a brief
description, the fault level or threshold and the action taken by the transmitter.
Table 6-1 Atlas Transmitter Fault List
TYPE
Description
Fault Level or Threshold
Transmitter
Action
Three
Strike
RFM1 CAB
FWD
RF Monitor #1, Cabinet
Forward Power
Threshold is fixed at +/-10%
of nominal
WARNING
NO
RFM1 SYS
FWD
RF Monitor #1, System
Forward Power
Threshold is fixed at +/-10%
of nominal
WARNING
NO
RFM1 CAB
RLFD
RF Monitor #1, Cabinet
Reflected Power
Trip point is set at
VSWR = 1.9:1
WARNING
YES
RFM1 SYS
RLFD
RF Monitor #1, System
Reflected Power
Trip point is set at
VSWR = 1.9:1
(Foldback starts at 1.4:1)
WARNING
YES
RFM1 DrvA
RF Monitor #1, Drive A
Trip point is 50% of nominal
as measured in the DCU
Drive Chain Switch
to alternate exciter if
available
NO
RFM1 DrvB
RF Monitor #1, Drive B
Trip point is 50% of nominal
as measured in the DCU
Drive Chain Switch
to alternate exciter if
available
NO
RFM1 RL1-8
(PA Cabinet
#1)
RF Monitor #1, Reject
Load #1-8 dissipation
exceeded
50mW at output of 500W
attenuator or 100mW at
output of 1kW attenuator
Fault OFF
NO
RFM2-8
RL1-8
(for multiple
cabinet
transmitters
only)
RF Monitor #2-8 (where
the RF Monitor # is
equal to the PA Cabinet
#), Reject Load #1-8
dissipation exceeded
50mW at output of 500W
attenuator or 100mW at
output of 1kW attenuator
Fault OFF
NO
AC High
AC Mains voltage has
exceeded 10% above
nominal
3 ph = 456vac
1ph = 264vac
WARNING
NO
AC Low
AC Mains voltage has
exceeded 15% below
nominal
3 ph = 323vac
1ph = 187vac
WARNING
NO
Phase Imb
AC line imbalance phase
to phase
If any phase is greater than
+/- 5% of the average of all
three phases
RF_MUTE and
PS_MUTE
NO
Phase
Sequence
AC 3-phase lines
connected in improper
sequence
Correct or Incorrect
LED on PS Monitor
Board
NO
Содержание Atlas DVL400
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...