2/25/03
888-2473-001
4-33
WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
ATLAS Series™
4.5.4.1
S1, PS Monitor Board Configuration Switches
There is a PS Monitor board installed in each PA cabinet to control and monitor the
supplies and to report back to the Main Controller in the #1 PA Cabinet. Dipswitch
S1 has 8 switches, which are used to set the cabinet ID and to configure the board so
that it knows how many and what type of supplies it is monitoring. Table 4-2 shows
the settings for all sections of S1. The switches set the following parameters:
a.
Cabinet ID - The number of the PA cabinet (1-8)
b.
Single or dual low voltage power supplies (LVPS)
c.
3 phase or single phase power
d.
Number of PA power supply modules
Table 4-2 S1, Switch Settings, PS Monitor Board
Function
S1-1
S1-2
S1-3
S1-4
S1-5
S1-6
S1-7
S1-8
CABINET 1
OFF
OFF
OFF
CABINET 2
NOTE:
The cabinet ID is carried to the
rest of the boards in the PA
cabinet via the LVPS Power
Bus cables connected to J8 and
J9.
OFF
OFF
ON
CABINET 3
OFF
ON
OFF
CABINET 4
OFF
ON
ON
CABINET 5
ON
OFF
OFF
CABINET 6
ON
OFF
ON
CABINET 7
ON
ON
OFF
CABINET 8
ON
ON
ON
ONE LVPS
OFF
TWO LVPS
ON
3 PHASE AC
OFF
1 PHASE AC
ON
1 PA SUPPLY
OFF
OFF
2 PA SUPPLY
OFF
ON
3 PA SUPPLY
ON
OFF
4 PA SUPPLY
ON
ON
SPARE
ON
SPARE
ON
Содержание Atlas DVL400
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...