2/25/03
888-2473-001
3-33
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ATLAS Series™
3.9.4.1
System Setup
This screen provides a way to change 3 important pieces of information which are
then used throughout the GUI.
a.
Station Name - This can be up to 24 characters and will appear at the top of
Every GUI screen.
b.
Model Number - This value is selected from a pull down list by touching the
white box. The model number chosen must match the transmitter name plate.
It is used to gray out portions of the GUI screens which are not used by some
models.
c.
Nominal Power Output (after all system filters) - This number is used for a
couple of things:
1.
It is used to set the 100% mark on the power bargraph at the top of
every GUI screen.
2.
It is used to calculate the VSWR foldback and fault thresholds, see
"3.7.3.2 Output Setup" on page 3-22.
The rest of the information on this page was set during factory test and cannot be
changed by the user. These include:
a.
Serial Number - Please note this for reference before calling for support.
b.
AC Line (VAC) Nominal - This number should reflect your nominal AC line
voltage as measured at the disconnect.
c.
AC Line Frequency (Hz) - 50 or 60Hz. Should reflect your line frequency.
d.
AC Phases - 1 or 3 depending on the model. Up to DVL 1100 will be single
phase or 1, while the DVL 1500 and up will be 3 phase. The number of ac
phases is set by a dipswitch setting on the PS Monitor board.
Figure 3-38 System Setup Screen
To Figure 3-39
To Figure 3-37
Содержание Atlas DVL1100
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...