2/25/03
888-2473-001
3-23
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
ATLAS Series™
3.8
Power Supply Main Menu
If you press the Power Supply button on the control
panel overlay, it will take you to the screen shown in
Figure 3-26. The Power Supply Menu structure is
shown inFigure 3-47 on page 3-39.
This is the overall Power Supply metering screen for both the PA Power Supplies
and the Low Voltage Power Supply Units or LV PSU and the AC Mains. It also
allows access to all other Power Supply screens:
•
PS Faults - Fault list and status
•
PS Meters - Detailed metering
•
PS Service - Help screen
Notice that this screen is also showing that PS4 has a fault and has basically shut off
at 0.1V. This also causes the power supply icon at the top right to turn red. This icon
would show up red on all screens until the fault is cleared.
This screen also shows that the transmitter is equipped with only 1 LV
PSU. The optional second LV PSU is grayed out. The Icon to the right is
an example of a Dual LV PSU transmitter where the second unit has a
fault. Pressing this button will take you to the PS Faults screen in Figure
3-27, as will the AC Mains button.
Figure 3-26 Power Supply Screen
To Figure 3-27
To Figure 3-28
To Figure 3-29
To Figure 3-3
Содержание Atlas DVL1100
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...