2/25/03
888-2473-001
2-29
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Series™
2.15.1 Remote Power Metering, J17
Each analogue metering output will provide 0 - 4.096Vdc output into a 400 ohm
load (where 3Vdc = Full Scale). The connections for J17 are listed in Table 2-5.
Table 2-5 J17, External I/O Board, Remote Power Metering
Connection
Schematic Label
Metered Parameter
J17-1
GND
Ground
J17-2
VOUTA
Total Forward Power (After Filter)
J17-3
VOUTB
Total Reflected Power (After Filter)
J17-4
VOUTC
Forward Power Cabinet #1 (Before Filter)
J17-5
VOUTD
Reflected Power Cabinet #1 (Before Filter)
J17-6
GND
Ground
J17-7
GND
Ground
J17-8
VOUTE
Forward Power Cabinet #2 (Or Spare)
J17-9
VOUTF
Reflected Power Cabinet #2 (Or Spare)
J17-10
VOUTG
Spare
J17-11
VOUTH
Spare
J17-12
GND
Ground