WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Series™
* Requires optional equipment
2.15 Remote Status Outputs, J15 & J16
All of the remote status outputs are open collector and will sink 100mA at up to
+24Vdc to provide an indication status is active. The pull up supply voltage for the
status indications can be supplied via J15 & J16 or can be supplied by an external
voltage source. The status output connections are listed in Table 2-4.
Table 2-4 J15 & J16, External I/O Board, Remote Status Outputs
Connector
Schematic Label
Status Output
J16-1
GNDB
Isolated Ground
J16-2
+5VDC_ISOLATED
Output - install jumper to J16-11 to use internal supply for
status pull ups. Otherwise an external supply will have to
be connected to J16-11.
J16-3
/OUTPUT 1
Off/On Status
J16-4
/OUTPUT 2
Life Support Status
J16-5
/OUTPUT 3
RF Mute Status
J16-6
/OUTPUT 4
Ext. Intlk Status - External Interlock Status
J16-7
/OUTPUT 5
Drive Chain Fault Status
J16-8
/OUTPUT 6
Power Amp Fault Status
J16-9
/OUTPUT 7
Output Fault Status
J16-10
/OUTPUT 8
Power Supply Fault Status
J16-11
+VDC_EXT_SUPPLY
Input For External Pull Up Supply Voltage
J16-12
GNDB
Isolated Ground
J15-1
GNDB
Isolated Ground
J15-2
+5VDC_ISOLATED
Output - install jumper to J15-11 to use internal supply for
status pull ups. Otherwise an external supply will have to
be connected to J15-11.
J15-3
/OUTPUT 9
Control Fault Status
J15-4
/OUTPUT 10
Cooling Fault Status
J15-5
/OUTPUT 11
Summary Fault Status
J15-6
/OUTPUT 12
Drive Chain A/B Select Status
J15-7
/OUTPUT 13
Pump A/B Select Status
J15-8
/OUTPUT 14
RF Switch A/B Status
J15-9
/OUTPUT 15
RF_SW_SEL_OUT (to motorised rf switch)
Содержание Atlas DVL1100
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...