6-4
888-2473-001
2/25/03
WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
ATLAS Series™
Fuse 1
Fuse failed on MOV
board
FUSE OPEN
WARNING
NO
Fuse 2
Fuse failed on MOV
board
FUSE OPEN
WARNING
NO
Fuse 3
Fuse failed on MOV
board
FUSE OPEN
WARNING
NO
Fuse 4
Fuse failed on MOV
board
FUSE OPEN
WARNING
NO
LVPS1 AC
(Single
LVPS
System)
No AC line voltage
present at input to LVPS
#1
AC_OK signal from the low
voltage power supply unit
RF and PS_MUTE,
and AC_LOW
NO
LVPS1 AC
(Dual LVPS
System)
No AC line voltage
present at input to LVPS
#1
AC_OK signal from the low
voltage power supply unit
WARNING if LVPS2
is operational. RF and
PS_MUTE, and
AC_LOW if both
supplies failed
NO
LVPS1 DC
(Single
LVPS
System)
LVPS #1
DC output fault
+15, -15 or +7.5Vdc
BUS_OK signal from low
voltage power supply unit
RF and PS_MUTE,
and AC_LOW
NO
LVPS1 DC
(Dual LVPS
System)
LVPS #1
DC output fault
+15, -15 or +7.5Vdc
BUS_OK signal from low
voltage power supply unit.
WARNING if LVPS2
is operational. RF and
PS_MUTE, and
AC_LOW if both
supplies have failed.
NO
LVPS2 AC
No AC line voltage
present at input to LVPS
#2
AC_OK signal from the low
voltage power supply unit
WARNING if LVPS1
is operational. RF and
PS_MUTE, and
AC_LOW if both
supplies have failed.
NO
LVPS2 DC
LVPS #2
DC output fault
+15, -15 or +7.5Vdc
BUS_OK signal from low
voltage power supply unit
WARNING if LVPS1
is operational. RF and
PS_MUTE, and
AC_LOW if both
supplies have failed.
NO
PA PS1 DC
PA Power Supply #1,
DC Output Fault
DC_OK signal from Power
Supply Unit
WARNING
NO
PA PS2 DC
PA Power Supply #2,
DC Output Fault
DC_OK signal from Power
Supply Unit
WARNING
NO
PA PS3 DC
PA Power Supply #3,
DC Output Fault
DC_OK signal from Power
Supply Unit
WARNING
NO
Table 6-1 Atlas Transmitter Fault List
TYPE
Description
Fault Level or Threshold
Transmitter
Action
Three
Strike
Содержание Atlas DVL1100
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...