Section 2 Installation / Initial Turn-On
ATLAS Series™
Figure 2-9 Module and Cabinet Phasing screen
2.14 Parallel Remote Control Connections
External Parallel remote control units can interface at the External I/O Board in the
rear of the cabinet. J13 through J17 are for remote Control, Status and Analogue
readings. The connectors are organised as follows:
•
J13 and J14 - Remote Transmitter Control Functions
•
J15 and J16 - Remote Status Outputs
•
J17 - Remote Analogue Metering Outputs
NOTE:
The forward slash ( / ) in front of a signal name means active low. The signal
/INPUT 1 for example is activated by momentarily bringing that input low.
Signal names without the forward slash are considered active high. This con-
vention is used throughout the schematics.
Detected rf sample
level, 0000 - 1023
PA Module Phase
Control Voltage
0000 - 1023
GOAL: To get the
detected rf sample
level readings
below 0030 (with
Gain set to LOW)
Press one of these
buttons
Module Group
select buttons
Reject Loads