2/25/03
888-2473-001
2-3
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
ATLAS Series™
•
843-5550-100, DVL 4300 and DVL 5700 - Additional PA Cabinet
Wiring Diagram. Only used with dual cabinet transmitters, this
schematic is used in addition to the 843-5550-004.
h.
Pump Module Outline Drawing - 843-5550-175
i.
Heat Exchanger Outline Drawing- 843-5550-176
2.3
Installation Checkboxes
Located to the left of each important step in the installation procedure is a checkbox
like the one to the left of this paragraph. As each step in the procedure is completed,
the box should be checked. This provides a quick confidence check at the end of the
procedure that no steps were skipped.
The primary goal of each step is also in
bold letters
, with the rest of the paragraph being support information toward that
goal.
NOTE:
In case of discrepancy between the connections listed in the schematics ver-
sus the information given in this installation section, the wiring information in
the schematics should be considered the most accurate. All connections listed
in this section should be verified with the schematics before initial turn on.
2.4
Transmitter Cabinet Placement
The transmitter cabinet should be placed where it will have approximately 1 meter
clearance on each side and in the back. The front of the transmitter should have a
clearance of at least 1.5 meters to allow access for removal and installation of the
PA and power supply modules. There are several equipment layout drawings
included in the drawing package to help plan the cabinet placement:
•
843-5550-136 (843-5550-173 for DVL 4300 and 5700) Transmitter
Outline Drawing
•
843-5550-169 171 (843-5550-172 for DVL 4300 and 5700) Rf
Equipment Layouts
•
843-5550-170 (843-5550-213 for DVL 4300 and 5700) - Cooling System
Layout
Remove the bolts holding the transmitter to the wooden pallet and carefully
slide the cabinet off the pallet.
Remove the front door from each cabinet and set it aside in a safe place for the
rest of the installation process.
Use shims or flat washers to make sure the transmitter is level and solid (not
rocking).
For 2 cabinet systems, PA Cabinet 2 (the one without the control panel)
Содержание Atlas DVL1100
Страница 4: ...888 2473 001 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 6: ......
Страница 8: ......
Страница 11: ......
Страница 12: ......
Страница 100: ...3 40 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 3 Operation ATLAS Series...
Страница 146: ...4 46 888 2473 001 2 25 03 WARNING Disconnect primary power prior to servicing Section 4 Theory of Operation ATLAS Series...