FAX 5/10/20/30/40KW
October 28, 2013
3
‐
17
888
‐
2720
‐
001
WARNING:
Disconnect
primary
power
prior
to
servicing.
Copyright
©2013,
Harris
Broadcast
•
Airflow
‐
Measured
on
PS
Interface
board
.
3.7.8
STATUS>>SW REVISIONS
Software
revisions
currently
installed
in
the
transmitter,
includes
Bootloader,
GUI
and
Application
software.
3.7.9
STATUS>>TEST
Test
mode
is
for
future
software
development.
Table 3-7 STATUS>SYSTEM Menu Description
Menu
Field
Description
SYS
SUM:OK
System
summary
OK,
Warning
or
Fault
APC
STATUS:ON
APC
Status
ON
or
OFF
APC
MODE:DRIVE
APC
Mode
DRIVE(APC
to
Exciters)
or
IPA(APC
to
the
IPA)
CTRL
MODE:NORM
Control
Mode
NORM
or
Backup
(Only
way
this
can
be
backup
is
Control
switch
S1
on
System
Interface
bd
is
set
to
BACKUP)
PWR
MODE:NORM
PWR
Mode
Norm,
LOW
or
UPS
INTERLOCK:OK
Interlock
status
OK
or
FLT(J1
‐
24
User
Interface)
RF
MUTE:NO
RF
Mute
NO
or
MUTED
REMOTE
MUTE:NO
Remote
Mute
NO
or
MUTED
EQUIP
INTLK:OK
Equipment
Interlock
OK
or
FLT(J1
‐
9
User
Interface)
SYSTEM
METERS
APC
REF:3.50V
APC
Reference
set
by
micro
during
system
calibration
APC
OUT:3.53V
APC
output
voltage,
changes
with
Raise/Lower
Power
PWR
LIMIT:0.00V
Power
Limit
0
V
until
the
110%
power
limit
is
reached
or
VSWR
Foldback
occurs(1.3:1
to
1.5:1)
FRONT
TEMP:41.0C
Front
Temperature
measured
on
Control&Display
Board(Indication
Only)
PA
BLOCK
x
FANS:OK
Status
of
fans
on
rear
door
of
power
block
OK
or
FAULT
AIRFLOW
STAT:OK
Status
of
airflow
sensor
OK
or
FAULT
REAR
TEMP:36.1C
Rear
Temperature
measured
on
Power
Supply
Interface
(Hot
Air
through
PA
Modules
and
power
supplies)
controls
fan
speed
AIRFLOW:90%
Percent
of
airflow
measured
on
Power
Supply
Interface
Board;
Typically
90%
under
normal
operating
conditions.
Ramps
up
to
100%
under
fault
conditions
and
higher
exhaust
temperatures