FAX 5/10/20/30/40KW
October 28, 2013
5
‐
3
888
‐
2720
‐
001
WARNING:
Disconnect
primary
power
prior
to
servicing.
Copyright
©2013,
Harris
Broadcast
Table 5-3 System Interface Board S2 (Rev G hardware and earlier)
Switch
Name
Schematic
Sheet
Default/
User
Setting
Description
S2
‐
1
APC
Hardware
Control
4
ON
ON
‐
for
hardware
control
of
APC
;
OFF
for
software
control
of
APC;
Software
control
of
APC
not
implemented
at
this
time.
If
switch
is
set
to
OFF
the
APC
will
not
function.
Table 5-4 System Interface Board S3
Switch
Name
Schematic
Sheet
Default/
User
Setting
Description
S3
‐
1
MUX
Unit
1
12
Model
For
FAX5/10,and
Power
Block
1
in
FAX20/30/40
ON;
All
others
OFF
S3
‐
2
MUX
Unit
2
12
Model
ON=Power
Block
2
FAX20/30/40;
All
other
OFF
S3
‐
3
MUX
Unit
3
12
Model
ON=Power
Block
3
FAX30/40;
All
other
OFF
S3
‐
4
MUX
Unit
4
12
Model
ON=Power
Block
4
FAX40;
All
other
OFF
S3
‐
5
System
Control
12
Model
ON=TX/System
Controller;
OFF=Power
Block
Controller
S3
‐
6
Config
4
Model
ON=Power
Block
Controller;
OFF=TX/System
Controller
S3
‐
7
Default
Mode
5
OFF
Used
on
TX/System
controller
only;
ON=TX
primary
mode
defaults
to
either
HD
mode
S3
‐
8
Default
Mode
5
ON
Used
on
TX/System
controller
only;
ON=TX
primary
mode
defaults
to
FM
Table 5-5 System Interface Board S5 (Exciter A) and S6 (Exciter B)
Switch
Name
Schematic
Sheet
Default/
User
Setting
Description
S5
‐
1
RS485
Enable
8
Model
Used
for
FAX
Exciter
S5
‐
2
FM_ON
Status
8
Model
Used
when
Exciter
has
FM
ON
Status
outputs
S5
‐
3
HD_ON
Status
8
Model
Used
when
Exciter
has
HD
ON
Status
outputs
S5
‐
4
Exciter
Ready
8
Model
ON
‐
When
Exciter
has
a
Ready
Status
Line
S5
‐
5
RF
Mute
Polarity
8
Model
ON=Mute
to
Exciter
Low;OFF=Mute
to
Exciter
Hi
S5
‐
6
RF
Mute
Polarity
8
Model
ON=Mute
to
Exciter
Hi;OFF=Mute
to
Exciter
Low
S5
‐
7
APC
Out
8
Model
ON=Exciter
has
External
APC
Input;
OFF
requires
the
APC
to
drive
the
IPA
and
S5
‐
8
(S6
‐
8)
should
must
be
ON.
S5
‐
8
Drive
Control
8
Model
ON=IPA
Drive
Control
(Exciter
has
no
External
APC
input):OFF=Exciter
APC
Control