Figure 5-14 System Interface Control Cables Removed
After the Module is removed, use a Phillips screw driver to remove the PWA from the metal housing it attached to by
removing 6 Phillips screws. Attach the replacement PWA to the metal housing. Set the dipswitches to match the
removed boards on Rev E and higher PWA’s. If replacing a PWA Rev D or earlier refer to Section 5.4.4 for a
description of each switch. The board will come in the factory default positions.
Verify system and power block calibrations are still correct.
5.8.3
Multi Unit System Interface Board Replacement
To replace the PWA in the Multi Unit System Interface Module, begin by removing the 2 front Phillip
screws securing the sheet metal tray the module is mounted on. Carefully slide the module out then remove
the 4 Phillips screws that attach the cover to the module.
Figure 5-15 Removing Multi Unit System Interface Control Module and Cover