Section-6 Diagnostics
October 28, 2013
6
‐
4
Copyright
©2013,
Harris
Broadcast
WARNING:
Disconnect
primary
power
prior
to
servicing.
888
‐
2720
‐
001
Figure 6-2 Interface Control Module Front LEDs
Refer
to
the
drawing
801
‐
0234
‐
051
sheet
9
of
13.
DS1:
+5V:
Illuminates
Green
when
the
+5
Volt
supply
for
the
controller
is
on.
5
V
typically
runs
4.6
VDC
DS2:
FWD
PWR:
Normally
OFF.
Illuminates
Yellow
when
the
Forward
Power
Limit
(<110%
of
calibrated
power)
is
reached
DS3:
VSWR
FB:
VSWR
Foldback:
Normally
OFF.
Illuminates
Yellow
when
the
VSWR
threshold
(1.3:1
to
1.5:1depending
on
user
setting)
is
exceeded
and
the
transmitter
goes
into
Power
Foldback
mode.
DS5:
EXT
INTLK:
External
Interlock:
OFF
when
Interlock
circuit
is
complete.
Illuminates
Red
when
Interlock
circuit
is
open
User
Remote
J1
‐
24
to
J1
‐
25.
Transmitter
will
fault
off
and
require
user
to
turn
transmitter
back
on.
DS7:
FLT
OFF:
System
Fault
OFF:
Normally
OFF.
Illuminates
Red
when
the
transmitter
Faults
OFF.
Check
other
status
LED’s
and
the
fault
log
for
further
information.
VSWR
Fault
greater
than
1.5:1
(not
Foldback)will
cause
a
System
Fault
Off,
also
an
airflow
fault
will
cause
the
system
to
fault
off.
DS9:
VSWR
FLT:
VSWR
Fault:
Normally
OFF.
Illuminates
Red
when
the
VSWR
threshold
(1.5:1)
is
exceeded.
This
will
also
cause
a
FLT
OFF
led
to
light.
DS11:
EQUIP:
Equipment
Interlock:
Normally
OFF.
Illuminates
Red
when
the
transmitter
Equipment
Interlock
circuit
J1
‐
9
is
grounded.
Transmitter
will
mute
until
the
interlock
J1
‐
9
of
USER
REMOTE
is
open,
then
transmitter
will
return
to
TPO.
DS28
System
LED
should
illuminate
as
well.
DS13:
AC
FLT:AC
Mains
Fault:
Normally
OFF.
Illuminates
Red
when
the
AC
Mains
input
voltage
drops
below
the
operating
range
of
the
power
supply.
This
fault
will
trip
when
the
AC
voltage
at
the
input
to
the
Power
Supply
Interface
board
drops
below
190
VAC
on
any
phase.
Verify
the
AC
Mains
to
the
transmitter
is
within
the
range
for
Содержание Flexiva FAX 10KW
Страница 2: ......
Страница 8: ......
Страница 10: ...WARNING Disconnect primary power prior to servicing ...
Страница 167: ......