FAX 5/10/20/30/40KW
October 28, 2013
6
‐
5
888
‐
2720
‐
001
WARNING:
Disconnect
primary
power
prior
to
servicing.
Copyright
©2013,
Harris
Broadcast
the
service
being
used
(single
or
3
‐
phase).
Check
fuses
for
low
voltage
detector
on
each
phase
on
the
Power
Supply
Interface
board
in
rear
of
power
blocks.
Verify
cabinet
or
wall
circuit
breaker
has
not
tripped.
DS15:
LOAD
FLT:
Reject
load
Fault:
Normally
OFF.
Illuminates
Red
when
a
fault
in
the
combiner
reject
load
occurs.
This
fault
is
either
a
fan
has
failed,
the
temperature
in
the
reject
load
has
exceeded
fault
level,
or
the
reject
load
input
power
is
high.
If
a
reject
load
fault
has
occurred
the
transmitter
will
automatically
switch
to
Low
Power
Mode,
approximately
quarter
power.
Power
Reference
voltage
will
drop
to
2.7
VDC.
DS17:
RF
MUTE:
Normally
OFF,
lights
when
the
RF
is
muted
by
a
TX
OFF
command.
DS19:
Exciter
Not
Ready;
Normally
OFF.
Illuminates
Yellow
when
the
Exciter
is
muted.
Check
Exciter
manual
for
further
information.
DS20:
DRV
CHN:
Drive
Chain:
Normally
OFF.
Illuminates
Yellow
when
the
IPA
is
muted.
This
will
occur
when
switching
to
the
backup
IPA.
DS21:
REMOTE:
Remote
Mute:
Normally
OFF.
Illuminates
Yellow
whenever
a
RF
mute
occurs.
Check
J1
‐
7
of
USER
REMOTE
for
ground
which
mutes
the
transmitter.
DS4:
FM:
Illuminates
Green
when
the
transmitter
is
in
FM
Mode.
DS6:
FM+HD:
Illuminates
Green
when
the
transmitter
is
in
FM
+
HD
Mode.
DS8:
HD:
Illuminates
Green
when
the
transmitter
is
in
HD
Mode.
DS10:
MUX:
Flashes
with
MUX
activity.
This
should
flash
all
the
time.
DS12:
APC
OFF:
Normally
OFF.
Illuminates
Yellow
when
the
APC
is
turned
OFF.
APC
will
be
disabled
when
there
are
faults
in
the
system
such
as
failed
PA
module
or
PS
module.
Check
other
LED’s
and
the
fault
log
for
further
information.
This
can
also
be
turned
off
manually
in
the
LCD
Menu
tree.
DS14:
EXC
B:
Normally
OFF.
Illuminates
Yellow
when
the
backup
Exciter
is
switched
into
the
Drive
Chain.
DS16:
LOW
PWR:
Normally
OFF.
Illuminates
Yellow
when
the
transmitter
is
switched
to
the
Low
Power/UPS
mode
via
J1
‐
8
or
USER
REMOTE.
This
will
also
occur
when
the
Reject
Load
has
a
fault
(Fan,
RF
or
Temp).
DS18:
RESTRIKE:
Normally
OFF.
Momentarily
illuminates
Yellow
when
the
transmitter
experiences
an
ON
command
pulse.
This
could
be
from
an
AC
power
failure,
a
High
VSWR,
etc.
If
the
transmitter
does
not
come
ON
and
stay
ON,
another
Restrike
occurs.
If
the
transmitter
does
not
stay
ON
after
the
3rd
Restrike,
it
stays
OFF.
DS34:
IPA
CTRL:
APC
to
IPA:
Illuminates
when
the
transmitter
is
setup
for
APC
to
drive
the
IPA
DS31:
EXC:
Exciter:
Normally
OFF.
Illuminates
Red
when
an
on
‐
air
Exciter
fault
occurs.
Check
Exciter
manual
for
further
information.
DS30:
DRV:
Drive
Chain
Summary
Fault:
Normally
OFF.
Illuminates
Red
when
an
IPA
fault
occurs.
Check
fault
Log
for
further
information.
DS32:
PA:
Power
Amplifier
Summary
Fault:
Illuminates
Red
when
any
type
of
PA
fault
occurs.
Check
fault
Log
for
further
information.
DS29:
PS:
Power
Supply
Summary
Fault:
Normally
OFF.
Illuminates
Red
when
any
type
of
PS
fault
occurs.
Check
fault
Log
for
further
information.
DS33:
OUT:
Output
Summary
Fault:
Normally
OFF:
Illuminates
Red
when
any
type
of
RF
output
fault
occurs.
Check
fault
Log
for
further
information.
DS28:
SYS:System
Summary
Fault:
Normally
OFF.
Illuminates
Red
when
any
fault
in
the
transmitter
system
occurs.
Check
fault
Log
for
further
information.
Содержание Flexiva FAX 10KW
Страница 2: ......
Страница 8: ......
Страница 10: ...WARNING Disconnect primary power prior to servicing ...
Страница 167: ......