FAX 5/10/20/30/40KW
October 28, 2013
6
‐
9
888
‐
2720
‐
001
WARNING:
Disconnect
primary
power
prior
to
servicing.
Copyright
©2013,
Harris
Broadcast
Figure 6-6 Telnet Page 3/7 Power Block Control/Status
Display
shows
status
of
each
item
that
is
part
of
each
Power
Block.
In
a
FAX30/40
pressing
(2)
will
display
status
and
values
for
power
blocks
3
and
4,
pressing
(1)
will
switch
display
back
to
power
blocks
1
and
2.
The
Status
1
‐
6
in
the
top
sections
of
the
screen
will
correspond
to
the
LED’s
on
the
System
Interface
Board
in
each
power
block.
Figure 6-7 Telnet Page 4/7 PA Modules Status/Meters
Displays
IPA
and
PA
Module
Fault
status,
Current,
PA
Volts
and
PA
Temp.
In
a
FAX30/40
pressing
(2)
will
display
status
and
values
for
power
blocks
3
and
4,
pressing
(1)
will
switch
display
back
to
power
blocks
1
and
2.
Fault
status
bits
are
displayed
as
shown:
b0/b1/b2/b3/b4/b5
b0
=
PA
Overdrive
‐
greater
than
25
Watts
into
module
b1
=
VSWR
Fault
‐
greater
than
100
W
reflected
into
module.
Depends
on
frequency,
load
and
phase
angle.
b2
=
Under
Voltage
Fault
‐
b3
=
Overcurrent
Fault
‐
Greater
than
30
Amps
current
draw
on
pallet
b4
=
Overtemp
Fault
‐
faults
at
95
C
b5
=
Module
not
Present
Fault