42
1003370 05/2016 V01
Table 42.2 Error numbers
Table 42.3 IP adress menu
Error numbers
Meaning
17
Parameter reset to factory settings failed
18
Parameter write access failed
19
Save parameter data set non volatile failed
20
Not all parameters written
21
Error while reset to factory settings
4.4.4 Ethernet IP adress menu (IP)
An Ethernet TCP/IP port is available as a service and diagnostics interface. The IP address is set by default to
192.168.39.5 and the subnet mask to 255.255.255.0. Both can be changed by way of the IP Address menu.
Menu level
Para-
meter
Value
range
Meaning
Explanation
1
2
IP
Iu
b0
00..FF
IP address udate
Byte 0
Setting of byte 0 of the IP address in hexadecimal format
(e. g. „05“ for 192.168.39.
5
)
b1
00..FF
IP address udate
Byte 1
Setting of byte 1 of the IP address in hexadecimal format
(e. g. „27“ for 192.168.
39
.5)
b2
00..FF
IP address udate
Byte 2
Setting of byte 2 of the IP address in hexadecimal format
(e. g. „A8“ for 192.
168.
39.5)
b3
00..FF
IP address udate
Byte 3
Setting of byte 3 of the IP address in hexadecimal format
(e. g. „C0“ for
192.
168.39.5)
Ir
–
–
IP reset to factory
setting
Reset IP address to factory default
(192.168.39.5)
Su
b0
00..FF
Subnetmask udate
Byte 0
Setting of byte 0 of the IP address in exadecimal format
(e. g. „00“ for 255.255.255.
0
)
b1
00..FF
Subnetmask udate
Byte 1
Setting of byte 1 of the IP address in hexadecimal format
(e. g. „FF“ for 255.255.
255
.0)
b2
00..FF
Subnetmask udate
Byte 2
Setting of byte 2 of the IP address in hexadecimal format
(e. g. „FF“ for 255.
255
.255.0)
b3
00..FF
Subnetmask udate
Byte 3
Setting of byte 3 of the IP address in hexadecimal format
(e. g. „FF“ for
255
.255.255.0)
Sr
–
–
Subnetmask reset
to factory setting
Reset subnet mask to factory default setting
(255.255.255.0)
Menu level
Para-
meter
Value
range
Meaning
Explanation
1
2
PA
Pr
Parameter reset
Reset device settings to factory defaults
4.4.3 Parameters menu (PA)
On the Parameters menu the device settings can be reset to their factory defaults.
Error numbers
A failed user action is indicated by an error message. The message consists of an alternating display of “Er” and the
error number.
Note:
The error messages displayed during user input should not be confused with drive error messages. For detailed
informa tion on the error codes and on error management refer to the “YukonDrive® Operating Manual”.
Table 42.1 Parameters menu