17
V01 05/2016 1003370
Detail 1: Motor cable
At the motor connection (X1) of the YukonDrive® note the
following points:
• Secure one of the two supplied shield connection plates by
the screw to the mount on the top of the unit. Ensure the
plate contacts across a wide area with the heat sink of the
YukonDrive® and with the backing plate. Use a toothed
ring.
• Strip back the shield of the motor cable on the motor con-
nection (X1) of the YukonDrive® as little as absolutely nec-
essary.
• Connect the motor cable shield across a wide area to the
shield connection plate by the clamp supplied.
Note:
Ready made-up motor cables are available for Harmonic
Drive® servo motors.
Detail 2: Control supply (+24 V DC)
At the control supply connection (X2):
• Secure the second of the two supplied shield connection
plates by the screw to the mount on the bottom of the
unit. Ensure the plate contacts across a wide area with the
heat sink of the YukonDrive® and with the
backing plate. Use a toothed ring.
• Slot a shield tube over the control supply cable and strip it
back only as short as necessary before the control sup ply
connection (X2).
• Connect the shielding tube of the control supply cable
across a wide area to the shield connection plate by the
clamp supplied.
Illustration 17.1 Specimen setup - Detail 1:
Motor cable
X1
Illustration 17.2 Specimen setup - Detail 2: Control supply
X2