LSA-10A-30-D-130 Technical Document
-23-
4-6-2 Enable Input (ENABLE)
The signal input of GND level will turn on the servo loop (motor maintains positioning) and the equipment
is ready for operation. The servo loop will turn off (motor becomes free) while the signal input is high
level (open). Examples of connections are as follows.
Note: Please do not turn on the power supply while ENABLE is ON
♦
Enable Connection Example 1
♦
Enable Connection Example 2
♦
Enable Connection Example 3
PSM Side
PSM Side
PSM Side
Ground (Heat Sink)
Ground (Heat Sink)
Ground (Heat Sink)