LSA-10A-30-D-130 Technical Document
-20-
Product
Label
Adjustment
Label
4-3 Dimensions (Third Angle Method)
The dimensions of the PSM-130 are as follows.
Note: Please confirm the details of the dimension with the supplied specification diagram issued by our
company.
4-4 Environmental Specifications
The environmental specifications of the PSM-130 are as follows.
No.
Items
Specifications
Remarks
1
Operating
Temperature [°C]
0
~
40
2
Humidity [%RH]
20
~
85
No condensation
3
Storage
Temperature [°C]
-
10
~
70
4
Humidity [%RH]
20
~
90
No condensation
5
Vibration
Resistance
(*1)
Vibration
Acceleration [m/s
2
]
24.5
Testing Conditions
Frequency: 10→1000→10 [Hz]
Time: 1 Cycle 20 [min]
No. of Times: 3 times each in x, y,
and z directions.
6
Shock
Resistance
(*1)
Vibration
Acceleration [m/s
2
]
294
Testing Conditions
Shock Time: 11 [ms]
No. of Times: 3 times each in x, y,
and z directions.
*1 The vibration/shock resistance tests are to ensure there is no degradation in performance during
non-operation period, but they do not guarantee the performance while operating.
Unit: mm
Heat Release
Fin