Chapter 9 - Torubleshooting and Repair
9-9
FIG. 9-4 USING A VOLTMETER TO CHECK LOAD CELL VOLTAGE
Result 1. If the voltage fluctuates with the weight the problem is exter-
nal.
Result 2. If the voltage does not fluctuate with the weight, call your
local representative or
Hardy Process Solutions
Customer Support Department.
Feeder Motor Won't Start
TROUBLE
PROBABLE CAUSE
REMEDY
When pushing the Start
button it does not acti-
vate the motor controller
(Analog Control) on the
feeder.
1.
Wiring to Analog Control
Connector is incorrect.
2.
Output configuration
jumpers are not set cor-
rectly for the feed back
signal.
3.
Feeder motor malfunc-
tion.
1. Check the wiring to the
Control Output con-
nector: (See Fig. 9-5)
For Jumper Settings
See Chapter 4)
Pin 1 = +Voltage
Pin 2 = -Voltage
Pin 5 = -Current
Pin 6 = +Current
2. Check the jumper set-
tings on the Control
Output board. (Prt.
#0535-0406) (See Fig.
9-6)
3. Switch the controller to
manual operating
mode. (See Chapter 7
for instructions)
Содержание HI 2160RC PLUS
Страница 1: ...HI 2160RCPLUS Rate Controller Operation and Installation Manual ...
Страница 23: ...HI 2160RCPLUS MANUAL 2 6 ...
Страница 32: ...Chapter 3 Installation 3 9 FIG 3 12 FRONT PANEL WITH BRACKETS FROM FACTORY FIG 3 13 BEZEL INSTALLATION DIAGRAM ...
Страница 46: ...Chapter 3 Installation 3 23 Interconnect Wiring Diagram See Fig 3 33 FIG 3 33 INTERCONNECT WIRING DIAGRAM ...
Страница 48: ...Chapter 3 Installation 3 25 FIG 3 35 SECURE MEMORY MODULE FIG 3 36 INSTALLING REMOVING SECURE MEMORY MODULE ...
Страница 49: ...HI 2160RCPLUS MANUAL 3 26 ...
Страница 67: ...HI 2160RCPLUS MANUAL 4 18 ...
Страница 91: ...HI 2160RCPLUS MANUAL 5 24 ...
Страница 151: ...HI 2160RCPLUS MANUAL 7 12 ...
Страница 187: ...HI 2160RCPLUS MANUAL 8 36 ...
Страница 197: ...1 2 3 4 5 6 V V I I VOLTAGE CURRENT HI 2160RCPLUS MANUAL 9 10 FIG 9 5 CONNECTOR WIRING DIAGRAM FOR CONTROL OUTPUT CARD ...
Страница 207: ...HI 2160RCPLUS MANUAL 9 20 ...
Страница 219: ...Data Worksheets WKSHT 6 ...