ANALOG OUTPUT MENU
RATE OF CHANGE
ZERO (L/M ) 1. 000
SPAN (L/M) 1 0. 000
HI 2160RC
PLUS
MANUAL
6-48
FIG. 6-42 ANALOG OUTPUT MENU/ZERO AND SPAN VOLTAGE
SETTING
Step 7. Press the Clear button to clear the entry.
Step 8. Use the numeric keys to enter the new value.
Step 9. Press the Enter button to accept the new value.
Step 10. If the SPAN value is equal to the ZERO value an error prompt
appears. Change the SPAN value so that ZERO and SPAN are
not equal.
Step 11. Press the Enter button to accept the new setting.
Step 12. Press the Exit button until you reach the Operational Display.