HI 2160RC
PLUS
MANUAL
5-14
Automatic Rate
Calibration
Procedures
NOTE:
If the density of the material changes significantly, a new rate calibration should be
performed.
WARNING
MAKE SURE THAT THE SYSTEM IS READY TO BE CALIBRATED. AS
SOON AS THE START/ENTER BUTTON IS PRESSED THE FEEDER WILL
TURN ON AND CALIBRATE ITSELF.
•
Complete all Pre-Calibration, Calibration Setup and Feeder Verifi-
cation Procedures FIRST.
Setting REC to Zero
Step 1. Press the Config/1 button. The Sequence display appears.
Step 2. If the instrument is being calibrated for the first time, use the
numeric keys and enter the default High Code Value numbers
"1,2,3,4".
Step 3. If there is a High Code Value other than the default number,
enter that number.
Step 4. Press the Enter button. The main menu appears.
Step 5. Press the down arrow
↓
button until the cursor is next to the
Tuning/Control sub-menu.
Step 6. Press the Enter button.
Step 7. Press the down arrow
↓
button until the cursor is next to the
REC LEVEL.
Step 8. Press the -/Clear button. The REC level should display 0.
Step 9. Press the Enter button. Entry accepted flashes momentarily on
the display.
Step 10. Press the exit button to exit the Tuning/Control sub-menu.
Enter the PAUSE
TIME Value
Step 1. Press the down arrow
↓
until the cursor is next to the Rate
Calibration sub-menu
Step 2. Press the Enter button. The Rate Calibration sub-menu
appears.
Step 3. Press the down arrow
↓
until the cursor is next to the PAUSE
TIME sub-menu.
Step 4. The Default setting is 5 seconds.
Step 5. The Pause Time can be a value between 1-999.
Step 6. All values are in seconds.
Step 7. Pause Time is the time you want the feeder to wait between
auto rate calibration cycles. If necessary more material may
be added to the feeder.
NOTE:
If a feeder is manually paused before a cycle starts, or during a cycle, when the cycle
is restarted it will run for the full feed time.
Step 8. Press the Clear button to clear the Pause Time value.
Step 9. Use the numeric keys to enter the new Pause Time value.
Step 10. Press the Enter button to accept the new value.
Содержание HI 2160RC PLUS
Страница 1: ...HI 2160RCPLUS Rate Controller Operation and Installation Manual ...
Страница 23: ...HI 2160RCPLUS MANUAL 2 6 ...
Страница 32: ...Chapter 3 Installation 3 9 FIG 3 12 FRONT PANEL WITH BRACKETS FROM FACTORY FIG 3 13 BEZEL INSTALLATION DIAGRAM ...
Страница 46: ...Chapter 3 Installation 3 23 Interconnect Wiring Diagram See Fig 3 33 FIG 3 33 INTERCONNECT WIRING DIAGRAM ...
Страница 48: ...Chapter 3 Installation 3 25 FIG 3 35 SECURE MEMORY MODULE FIG 3 36 INSTALLING REMOVING SECURE MEMORY MODULE ...
Страница 49: ...HI 2160RCPLUS MANUAL 3 26 ...
Страница 67: ...HI 2160RCPLUS MANUAL 4 18 ...
Страница 91: ...HI 2160RCPLUS MANUAL 5 24 ...
Страница 151: ...HI 2160RCPLUS MANUAL 7 12 ...
Страница 187: ...HI 2160RCPLUS MANUAL 8 36 ...
Страница 197: ...1 2 3 4 5 6 V V I I VOLTAGE CURRENT HI 2160RCPLUS MANUAL 9 10 FIG 9 5 CONNECTOR WIRING DIAGRAM FOR CONTROL OUTPUT CARD ...
Страница 207: ...HI 2160RCPLUS MANUAL 9 20 ...
Страница 219: ...Data Worksheets WKSHT 6 ...