Appendix
Technical specifications
Variant
cPµ1
Power line
For lead up to. 5×4 mm² at maximum
Rated nominal voltage
230 / 400 V
Rated nominal current
16 A / 20 A, 3-phase / 1-phase
Nominal frequency
50 Hz
Maximum charging capacity
11 kW
Protective switches
DC fault current detection 6 mA (built in);
additionally required:
fault-current circuit breaker Type A, 40 A,
0,03 A and an automatic cut-out C16 A/
C20 A
Charging cable
1 x Type-2, 20 A/16 A; 1 x Type-1, 16 A
Charging controller
EVCC (charge controller phoenix)
Load management
Dynamic with external eCB1 module
Environmental temperature
-30 to 50° C
Storage temperature
-30 to 85° C
Relative humidity
5 to 95% (not condensing)
Class of protection
I
Over-voltage category
III
Degree of contamination
3
Type of protection for cover
IP44
Dimensions
283 mm x 196 mm x 88 mm (HxWxD)
Weight per unit
Approx. 5.5 kg
Product number
3M3XXXX
Instruction Manual
cPµ1
charging station
Version: 1.3.5
23