Taking into operation and charging
process
After the mechanical and the electrical installation, your charging station is
immediately ready. The cPµ1 possesses a Type 1 or Type 2 charging cable
complying with IEC 62196-2 for charging (depends on variant).
Th
e Type-2 charging cable of the cPµ1
has three live conducting pins, a neutral
conductor, a PE conductor and two
signalling contacts (
C
ontrol
P
ilot and
P
roximity
P
ilot), which provide a safe
connection without danger.
Only when the plug of the charging cable
is interlocked with the charging socket,
voltage will be output through the
conducting pins and the charging
process will start.
The cPµ1 is equipped with a DC fault-
current-circuit
breaker
which
automatically interrupts in case of
leakage current. Thereby it is not
necessary to install a Type B fault-
current-circuit-breaker in the pre-
distributor. A Type A fault current circuit
breaker suffices.