Interruptions of operation and solutions
The cPµ1 executes internal testing routines to guarantee proper and safe
operation. In order to restore the previous operation state, first, it is essential
that you determine the type of malfunction undoubtedly.
DANGER!
Inside the charging station life threatening voltages occur!
Opening the charging station and following works on the
charging station
must be carried out solely by qualified staff.
The following malfunctions can occur:
Malfunction Possible cause
Proposal for solution
The LEDs are
not working
The cPµ1 is not provided
with any voltage
The external power supply of the cPµ1 is
interrupted: Please check the fuses and
protective switch of the pre-installation,
located in the lead.
If that doesn’t remove the error please
contact your local distributor.
The LEDs of the display are
damaged.
If the LEDs are defect please contact your
local distributor or the previously deployed
electrician so they can be exchanged.
The electric
vehicle is not
recognized.
The charging cable is not
plugged in correctly.
Remove the charging plug from the vehicle
and plug it in once again. Make sure that the
cable is set correctly in the socket of the
vehicle. If that doesn’t remove the
malfunction please contact your local
distributor or the previously deployed
electrician.
The vehicle is configured
faultily.
Check the settings of your vehicle and
restore them to pre-setting if needed. If that
doesn’t remove the error please contact your
local distributor and/or the previously
deployed electricians.
The LEDs
display an
error
sequence.
The cPµ1 recognizes a
malfunction
(See page 22)
Please contact your local distributor and/or
the previously deployed electricians.
Instruction Manual