5 - Operation
88
Filling Powder Chemicals by using HARDI TurboFiller
1.
Fill the main tank at least 1/2 with water (unless otherwise stated
on the chemical container label). See section “Filling of water”.
2.
Turn the handle of the suction valve towards “suction from Main
tank”. Turn pressure valve to closed position. Turn the
AgitationValve towards “agitation” if required. Close remaining
valves.
μ
ATTENTION! For increased suction from the TurboFiller the
AgitationValve can be kept closed.
μ
ATTENTION! If filling water from an external tank, this can be
continued while doing the next steps.
3.
Engage the pump and set PTO speed at 540 rpm.
4.
Open TurboFiller lid. Open TurboDeflector valve and TurboFiller
suction valve.
5.
Measure the correct amount of powdered chemical and sprinkle it
into the hopper as fast as the transfer device can flush it down. The TurboFiller suction valve must be open for at least
20 seconds after the chemical is no longer visible in the hopper in order to completely empty the transfer hoses into
the main tank.
€
DANGER! If the TurboFiller and the transfer hoses are not completely emptied, there is a risk of chemicals being
sucked out of the main tank!
€
DANGER! Always wear face shield and other appropriate personal safety equipment, when filling chemicals.
6.
If the chemical container is empty, it can be rinsed by the Chemical Container Cleaning device. Place the container
over the multi-hole nozzle and push the upper lever to the left of the TurboFiller.
€
DANGER! In order to avoid spray liquid hitting the operator, do not press lever unless the multi-hole nozzle is covered
by a container, as spray liquid may otherwise hit the operator!
μ
ATTENTION! The rinsing device uses spray liquid to rinse containers for concentrated chemicals. Always rinse the
chemical containers with clean water several times, until they are clean before disposal.
7.
Flush the TurboFiller with clean water from the rinsing tank or from an external tank by shifting to suction. The
TurboFiller suction valve must be open for at least 20 seconds after the rinse water is no longer visible in the hopper,
in order to completely empty the transfer hoses into the main tank.
μ
ATTENTION! If not flushed with clean water, the hopper rinsing device uses spray liquid for rinsing the hopper!
Cleaning the TurboFiller must always be done, when the spray job is ended, and together with cleaning the entire
sprayer. A cleaning after the last filling, and before spraying, does not ensure a clean TurboFiller!
8.
Close TurboFiller suction valve, when the hopper has been rinsed. Close the lid.
9.
If closed, turn the AgitationValve towards “agitation”.
Содержание RANGER PRO VH
Страница 4: ...1 EU Declaration 4 ...
Страница 10: ...Table of Contents 6 ...
Страница 108: ...5 Operation 104 ...
Страница 111: ...6 Maintenance 107 Boom Lubrication Oiling Plan Lubrication Oiling Plan Trailer Paralift ...
Страница 142: ...6 Maintenance 138 ...
Страница 149: ...8 Technical Specifications 145 Pump Specifications Pump Model 364 5 5 Pump Model 364 7 0 Pump Model 364 10 0 ...
Страница 164: ...Index 160 ...
Страница 166: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...