6 - Maintenance
122
Valves
2.
Loosen the 4 head bolts (1).
3.
Remove the head (2).
4.
Change the valves (3) - note their orientation, so that they are
replaced correctly!
μ
ATTENTION! It is recommended to use new gaskets (4), when
changing or checking the valves.
Diaphragms
5.
Loosen the diaphragm bolt (5).
6.
Remove the diaphragm washer (6).
7.
The diaphragm (7) may then be changed.
8.
Check that the drain hole (8) at the bottom of the pump is not
blocked.
9.
Apply a small amount of pump grease on the underside of the
diaphragms (between diaphragm and conrod washer).
10.
Reassemble the pump with the following torque setting.
•
Diaphragm head bolts (1): 90 Nm.
•
Diaphragm bolt (5): 90 Nm.
11.
Refit the plastic covers (C).
÷
NOTE! The diaphragm bolt on 1000 rpm pumps must be secured with locking compound.
μ
ATTENTION! Before tightening the 4 bolts for the head (2), the
diaphragm must be positioned between centre and top to
ensure correct sealing between diaphragm pump housing and
diaphragm cover. Turn the crank shaft if necessary.
C
C
1
2
3
3
3
4
4
5
6
7
8
Содержание RANGER PRO VH
Страница 4: ...1 EU Declaration 4 ...
Страница 10: ...Table of Contents 6 ...
Страница 108: ...5 Operation 104 ...
Страница 111: ...6 Maintenance 107 Boom Lubrication Oiling Plan Lubrication Oiling Plan Trailer Paralift ...
Страница 142: ...6 Maintenance 138 ...
Страница 149: ...8 Technical Specifications 145 Pump Specifications Pump Model 364 5 5 Pump Model 364 7 0 Pump Model 364 10 0 ...
Страница 164: ...Index 160 ...
Страница 166: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...